304 results found on Nordicsemi
Article22555 results found on DevZone
EOFlow’s EOPatch uses Nordic’s nRF52832 for wireless connectivity between wearable, controller and smartphone app
News
12/6/2021
Zwift Play controllers use Nordic nRF52832 SoC for processing and Bluetooth LE/ANT+ wireless connectivity
News
9/4/2023
Hisense’s XR-V3 employs Nordic’s nRF52832 SoC to provide stable and reliable Bluetooth LE connectivity between the handheld controllers and headset
News
8/28/2023
Unlimited’s eBike Kit employs Nordic’s nRF52832 SoC to enable electric power assist activation
News
7/6/2020
I-SYST’s BLYST840 and BLYST Nano modules employ Nordic’s nRF52840 and nRF52832 SoC WLCSPs to deliver high processing power in tiny form factor
News
11/26/2020
The ‘BETOP K1’ mechanical keyboard employs Nordic’s nRF52832 SoC to provide Bluetooth Low Energy wireless connectivity and extend battery life up to 30 hours between recharge
News
7/18/2018
The ‘SHP-DP930 Smart Doorlock’ employs Nordic’s nRF52832 SoC to deliver a low power, secure and stable wireless home or office security access solution.
News
6/6/2018
The new smart outlet employs Nordic’s nRF52832 SoC to act as the device’s central processor and provide wireless connectivity to the user’s smartphone or tablet
News
12/10/2018
Low-latency link between personal safety device and smartphone app allows the wearer to contact ‘guardians’ via a single button press in emergency situations
News
12/20/2017
Centurion Systems’ D5 SMART employs Nordic nRF52832 SoC for wireless setup and configuration from smartphone app via Bluetooth LE
News
2/18/2021
Hi, I have a central, where I want to close the BLE connection and restart the device. I have a button interrupt that does this: static void button_changed(uint32_t button_state, uint32_t has_changed){ int _err; if (has_changed & DK_BTN1_MSK) { printk("resetting the device.\n"); _err = bt_conn_disconnect(central_conn, BT_HCI_ERR_REMOTE_USER_TERM_CONN); printk("bt_conn_disconnect error: %d,\n", _err); bt_conn_unref(central_conn); central_conn = NULL; k_sleep(K_MSEC(1)); // reset the system //NVIC_SystemReset(); sys_reboot(0); } } However, when the device reboots. I get this warning and the scanner does not connect to the peripheral: The connection information is probably saved in a non-volatile memory, right? How do you properly disconnection the Bluetooth connection? Thanks for the help!!!
forum
11/14/2024
Hi, Might be possible to answer the question in bold. Thanks in advance! We have many BLE central NUS (Nordic UART Service) and many peripheral NUS communicating with each other. The BLE connection should always connect to the same pre-configured BLE device and it should be a one to one connection. In discovery/scanning it should connect to the first BLE device it finds and always connect to the same device. When a button is pressed, you can clear the configuration and select a different BLE device to connect to. So I thought using Filter accept list with a BLE address would be perfect for this, but I could not find any examples to help me. I found the devAcademy Filter Accept List example ( Lesson 5 Exercise 2 ) and the peripheral_accept_list example but only for the peripheral but I want to do this on the scanner site as the
forum
11/14/2024
I run project on SDK17 central example and added some code for advertising. But when elapsed 180 sec, my project starts from main again. I suppose, when called end of advertising, error appears and due to this error I got reset my project. Project from example with just advertising- works properly. After 180 sec advertisig disapears. I copied all functions from this project to my central project and got described problem. What settings should I check ? Thanks.
forum
11/14/2024
We are developing on the nRF52 Development Kit (nRF52 DK) for the nRF52832 SoC. Our application involves a 4-wire pipelined SPI communication with the Intan RHS2116 chip. According to the RHS2116 documentation (page 30, Picture 1), the SPI connection is configured such that the RHS2116 automatically outputs data two command cycles after a command is sent. This means that by the time we reach the 3rd command, there will be output data on MISO that we need to receive concurrently as the master (nRF52832) transmits the next command via MOSI. Our challenge is with the nRF Connect SDK and Zephyr OS: specifically, it’s unclear from Zephyr’s SPI library documentation if the spi_transceive function performs read and write operations within the same command cycle, which is required to meet the pipelined data flow of the RHS2116. Could you confirm if spi_transceive in the nRF Connect SDK supports simultaneous read/write operations in
forum
11/14/2024
With the mcuboot enabled, I'm not being able to disable the boot banners even by doing the below settings in prj.conf file. CONFIG_NCS_BOOT_BANNER = n CONFIG_BOOT_BANNER = n *** Booting MCUboot v2.1.0-dev-daf2946a0f07 *** *** Using nRF Connect SDK v2.7.0-5cb85570ca43 *** *** Using Zephyr OS v3.6.99-100befc70c74 *** I: Starting bootloader I: Primary image: magic=unset, swap_type=0x1, copy_done=0x3, image_ok=0x3 I: Secondary image: magic=unset, swap_type=0x1, copy_done=0x3, image_ok=0x3 I: Boot source: none I: Image index: 0, Swap type: none I: Bootloader chainload address offset: 0xc000 I: Jumping to the first image slot How do I disable this boot banner?
forum
11/14/2024
Hello. I would like to receive the passkey value that the user entered when pairing Bluetooth and modify it. Originally, it was said that if you enter "0000", you have to enter 6 digits according to the regulations to enable Bluetooth pairing. So if I type "0000" I want to add "00" and make it "000000". But I'm still a beginner, so I'd like to know where I can get the value and modify it. You want to modify passkey and use it in the function below that you want to compare with static_passkey.
forum
11/14/2024
I want to change static_passkey from "000000" to "0000". But It doesn't work when I update changed code to board. I changed like below pictures.(000000 -> 0000) And this is the code of PASSKEY Please help me.
forum
11/14/2024
Hi Nordic Support, Reaching out as due diligence on this. We've been relying on the HK100515NJ-T for L3 (15 nH DCC inductor), the recommendation from PCA10040, in our design. The part has reached EOL and we're considering replacements for it beyond the ones suggested by Digikey. https://www.digikey.com/en/products/detail/taiyo-yuden/HK100515NJ-T/957881#product-details-substitutes I would just like to know if there are any concerns worth considering when selecting this part beyond the 15nH 10% inductance and 50mA maximum current specified for L2 in series with it. Is there a concern with switching from ceramic core to air since this is a filtering inductor? Is there a limit to the DC resistance of the part you recommend staying below? Is there a reason you chose a part with 6x the current rating specified on the datasheet? Are you considering other parts going forward for the PCA10040 series? We're also considering https://www.digikey.com/en/products/detail/w%C3%BCrth-elektronik/7847804150/14640529 as an alt. Thanks, -Carl
forum
11/14/2024
Hi I want to run an epaper with the nRF52832 therefore is SPI needed. Board file was generated from scratch. In the devicetree I added the SPI modul and a epaper modul, which connects to the SPI modul. To send data to the epaper over SPI I use the spi_transceive_dt function. void EPaper_Spi_WriteByte(uint8_t txData) { uint8_t tx_buffer = 0x88; struct spi_buf tx_spi_buf = { .buf = (void *)&tx_buffer, .len = 1 }; struct spi_buf_set tx_spi_buf_set = { .buffers = &tx_spi_buf, .count = 1 }; struct spi_buf rx_spi_bufs = { .buf = &txData, .len = 1 }; struct spi_buf_set rx_spi_buf_set = { .buffers = &rx_spi_bufs, .count = 1 }; int err = spi_transceive_dt(&spiSpec, &tx_spi_buf_set, &rx_spi_buf_set); if (err < 0) { printk("SPI: spi_transceive_dt() failed, err: %d\n", err); return err; } } Chipselect and MOSI Signal ar working as requeried. But the SCL signal does nothing, it stays the whole time on low.
forum
11/13/2024
hello Nordic i am working with ncs v2.5.0 with nrf52840 and nrf52832 i use cbor for some command i build over smp (user groups >64).. i have this code part { zcbor_state_t *zse = ctxt->writer->zs; bool ok = true; uint32_t uptime_sec = (uint32_t)(k_uptime_get() / 1000); float temperature = temp_read(); #ifdef ONE_BAORD double temperature = 0; get_temp(&temperature); #elif defined (BOARD_X) || defined(BOARD_Y) float temperature = 0.0; get_temp(&temperature); #endif int16_t temperature_int = (int16_t)temperature; LOG_INF("temp %d, uptime %d", temperature_int, uptime_sec); ok = augu_status_encode_battery_mv(zse) && zcbor_tstr_put_lit(zse, FIELD_UPTIME_SEC) && zcbor_uint32_encode(zse, &uptime_sec) && zcbor_tstr_put_lit(zse, FIELD_TEMPERATURE) && zcbor_int_encode(zse, &temperature_int, sizeof(int16_t)) && ... return (ok ? MGMT_ERR_EOK : MGMT_ERR_EMSGSIZE); i see in the print of LOG_INF that the values are the same, i have no idea why temp changes with uptime rise and remain equal .. any ideas ??? and off course when i decode the cbor i get, using https://cbor.me/, i get that the temperature value is
forum
11/13/2024